UVP, LLC Header

  BioImaging Systems   |   Ultraviolet/Laboratory Products  |   Light Sources   |

BioSpectrum® Imaging System

The BioSpectrum Imaging System is configured with the 8.1 MP MegaCam 810 scientific grade CCD camera with dynamic 8.1 megapixel high resolution and high sensitivity capabilities. Researchers can not only capture fluorescent gel images, but can also be assured of superior sensitivity for low-light chemiluminescence applications as well.

The BioSpectrum is also available with the economical Chemi 415 Camera, offering native resolution of 1.4MP with selectable extension up to 7.4MP. The BioSpectrum offers a complete solution for automated picture perfect imaging in numerous research applications.


BioSpectrum Imaging System

Applications

System Name

Camera

BioSpectrum 810
MegaCam 810 Camera
BioSpectrum 600
OptiChemi 600 Camera
BioSpectrum 415
Chemi 415 Camera
BioSpectrum 310
GelCam 310 Camera
Click for Detailed Camera Info










Main Features
  • Choice of CCD Cameras include MegaCam 810 scientific grade CCD camera with 8.1 megapixels resolution, GelCam 310 Camera offering native resolution of 2.0MP with selectable extension up to 6.0MP and the Chemi 415 Camera, offering native resolution of 1.4MP with selectable extension up to 7.4MP.
  • Faster than film for western blot imaging
  • Assortment of CCD cameras including deeply cooled cameras
  • Motorized optics for setting the aperture, zoom and focus
  • Automated templates for repeat experiments
  • Light tight darkroom creates optimum imaging conditions
  • Unique viewing window is UV blocking for quick sample inspection
  • Built-in overhead white light and UV are easily selected from the software interface
  • Automated control of the five-position emission filter array
  • Easy access fold-down white light plate
  • Chemi tray fits over the plate for placement of blots
  • Roll-out tray provides easy access to the UV transilluminator
  • Select from several benchtop, patented and awarding winning transilluminator models (configured with system or optional)
  • VisionWorksLS Software (configured with system or optional)
  • BioLite ready
  • For multiple imaging applications including multiplex, chemiluminescent Western blots, fluorescent gels and colorimetric.
     
Software Interface
  • Automates your research for easy, yet accurate and repeatable results
  • Controls the motorized zoom lens, epi and transillumination UV and white light, emission filter selection and system power
  • Allows selection of user-defined or default settings
  • Select from SYBR Green (515-570mm), SYBR Gold (485-655mm), EtBr (570-640mm) filters or from other added filters
  • Click on the epi and transillumination light sources
  • Set templates and user preferences for recurring experiments

Transillumination

  • The white light plate folds down for illuminating samples such as coomassie blue stained or silver stained media
  • Operate the white light via the software interface
  • To use the transilluminator, slide the transilluminator out on the sliding tray and place samples on the filter surface
  • To fluoresce samples in the 460-470mm range, place the optional Visi-Blue Plate over the transilluminator surface

Chemiluminescent Imaging

  • The MegaCam 810, Chemi 415, and OptiChemi 600 cameras are cooled CCD cameras recommended for chemiluminescent imaging
  • For western blot and other chemiluminescent blots applications, place blots on the removable chemi tray
  • For chemiluminescent applications, place the chemi tray on top of the white light plate for placement of blots
  • Adjust the height of the tray to specific, repeatable positions
  • For western blot imaging, for application use information refer to the article titled "Ultra-Rapid and Ultra-Sensitive Detection of Proteins in Chemiluminescent Western Blotting"
  • For high sensitivity chemiluminescent 1D & 2D immunoblotting (western blotting) imaging
VisionWorksLS Image Acquisition and Analysis Software

VisionWorksLS Image Acquisition and Analysis Software can be configured with the system or ordered separately. Check with your local representative for details. This sophisticated package provides comprehensive tools for image capture and analysis of gels, plates and membranes as well as colony counting. Capabilities include:

  • Image acquisition functions for simple image capture and expanded integration options
  • Apply numerous image enhancements to images
  • Comprehensive tools for advanced 1D lane densitometry and analysis including area density, molecular weights and colony counting
  • Support for 21 CFR Part 11 compliance
  • One-touch automated macros
  • Define user profiles and preferences
  • Generate extensive reports and export data
  • Multiple user network license available
  • More …  
Green Initiatives

For companies and institutions concerned with green initiatives, UVP BioImaging Systems for chemiluminescence imaging eliminate the need for film or processing chemicals thereby enabling "green imaging."